On a compatible UGREEN NAS, use NVMe SSD cache when files should stay on an HDD volume and users frequently access the same small files. Choose a separate SSD pool for files or app data you want to store directly on the SSDs. Cache adds no usable storage capacity. UGREEN’s mixed-drive guide
Choose a cache mode or a separate pool
| Option | SSDs needed | Where the data lives | Example workload |
|---|---|---|---|
| Read-only cache | At least one compatible M.2 SSD | Original files stay on the HDD volume. The cache holds copies of frequently read data. | Browsing photo thumbnails or reopening small files. UGREEN cache guide |
| Read-write cache | Two compatible M.2 SSDs in RAID 1 | Incoming writes go to SSDs first, then sync to the HDD pool. | Multiple users frequently reading and writing small files. UGREEN cache guide |
| Separate SSD pool | Basic uses one SSD with no drive-failure tolerance. RAID 1 uses two matched SSDs and protects against one SSD failure. | The pool stores files or app data directly on its SSDs. | Docker application data or virtual-machine disks. UGREEN SSD pool guide |
For movie streaming, an HDD pool is usually a better fit. Sequential workloads like streaming see limited benefit from cache. UGREEN workload comparison
Check which NVMe SSDs fit
- Check the NAS slots. The DXP2800 and DXP4800 Plus each have two M-key slots for M.2 2280 NVMe SSDs. DXP2800 specs · DXP4800 Plus specs
- Match the exact SSD. In UGREEN’s compatibility list, select your exact NAS model, choose M.2 SSD, and match the SSD manufacturer’s model number to the results. UGREEN compatibility lookup
- Check the heatsink. For example, the DXP2800 list shows the Samsung 990 PRO 2TB as an M.2 2280 NVMe drive. The compatibility notes on that list exclude SSDs with heatsink covers. DXP2800 M.2 SSD list
For model comparisons, see DH4300 Plus vs DXP2800 and DXP4800 vs DXP4800 Plus.
For physical installation, select your exact NAS model in the Download Center and open Product Documentation. UGREEN Download Center
Create read-only or read-write cache in UGOS
- Sign in as an administrator and open Storage → Storage Pool & Volume. On the HDD pool, open the ··· menu, select SSD Cache Management, then select Create. The cache menu is absent for all-SSD pools. UGREEN cache setup
- Choose the HDD volume. Select Read-only cache or Read-write cache, then select Next. For read-write cache, acknowledge the delayed-write warning. A power interruption can cause loss of data still waiting to be written to the HDD pool. UGREEN cache setup
- Select the cache RAID type and the M.2 SSDs. Allocate cache capacity, then review the target volume, cache mode, RAID type, selected SSDs, and capacity. UGREEN cache setup
- Select Apply. In either cache mode, Format erases the selected M.2 SSDs. Copy anything you need from those drives elsewhere before choosing Format. Enter the administrator password to start creating the cache. UGREEN cache setup
Create a separate SSD pool and volume in UGOS
- Open Storage → Storage Pool & Volume, then select Create → Storage Pool. Select the unused M.2 SSDs and choose the RAID type. UGREEN SSD pool setup
- Set the volume capacity and choose a file system. Use Btrfs for snapshot recovery on supported folders or EXT4 if the pool mostly handles large sequential files and snapshots are unnecessary. Review the selected SSDs, RAID type, volume capacity, and file system. UGREEN SSD pool setup
- Pool creation formats the selected SSDs. Copy any existing data elsewhere before continuing. Select Create, acknowledge the formatting warning, and enter the administrator password. UGREEN SSD pool setup
If the goal is to fix slow file copies, UGREEN’s transfer troubleshooting guide shows how to run a controlled local transfer test. UGREEN transfer troubleshooting
Evidence and limits. UGREEN’s UGOS setup guide, model specifications, and compatibility documentation were checked on 28 November 2026. No hands-on testing was performed for this guide.